TOP

닫기

현재 위치
home > 생활용품 > 유아가구 > 기저귀교환대/기저귀갈이대/코알라/KB200

기저귀교환대/기저귀갈이대/코알라/KB200

상품 옵션
적립금
1%
판매가격
480,000
색상선택
사양선택

      총 상품 금액 0

      주문하기 장바구니 담기 찜하기

      detail prdoduct - 상품상세설명





      제품명 : 기저귀교환대
      MODEL NO : KB-200
      Wall Space : 889mm(W) X 565.15mm(H)
      Depth(Closed) : 101.6mm
      Depth(Open) : 551.4mm
      Color : Cream, Grey, White Granite, Earth



      친환경제품 환경을 오염시키지 않으며 인체에 무해한 제품
      미국FDA, 한국생활환경시험 연구원 KEMTI인증제품
      난연성제품 난연성SP소재를 사용하여 화재시 안전성 확보
      미국재료시험협회ASTM인증제품
      국제공인시험검사기관 시험성적서 발급
      에어쿠션
      기능
      소프트 폴리에틸렌 재질로 앉힐때 머리에 충격이 가해지지 않도록 에어쿠션기능이 있어 별도의 쿠션을 설치 하지 않아도 안전하게 사용할 수있음.







      ⊙ Durable frame withstands static loads up to 400 lbs(182kilos)
      ⊙ Steel on steel hinges re-inforce strength of unit
      ⊙ RDA approved blow-molded high density polyethylene conforms to ASTM G22,
         ANSI , A117.1, State of California OSHPD R-0367 and German TUV
      ⊙ Complies with ADA regulations when installed properly
      ⊙ Optional tamper resistant mounting hardware and factory installed lock secures
         station from vandalism
      ⊙ Braille instruments on door
      ⊙ Molded in usage and safety instructions(six languages)
      ⊙ Child protection straps hold child securely
      ⊙ Built in linerdispenser promotes good hygiene
      ⊙ Build in diaper bag holder provides extra convenience for parents




      MATERIALS:
      FDA approved injection-molded polypropylene with Microban® antimicrobial additive embedded into the bed surface. Reinforced steel-on-steel hinge mechanism and metal mounting chassis with mounting hardware included. Labelled usage instructions and safety messages in four languages. Optional Braille label available. Contoured changing surface area is 450 sq. in (11,430 sq. mm) and comes complete with nylon safety strap and bag hooks. Dual cavity liner dispenser holds approximately 50 KB150-99 bed liners.

      OPERATION:
      Concealed pneumatic cylinder and metal mounting chassis provides controlled, slow opening and closing of bed. Polypropylene is easy to clean and resists odors and bacterial growth. Complies with ASTM static load performance requirements when properly installed.
      Warning: To ensure that the unit supports the intended loads, baby changing stations must be properly installed according to the manufacturer’s instructions.

      SPECIFICATION:
      Baby changing station body shall be durable, injection-molded polypropylene. Design of unit shall be surface-mounted. Unit shall be equipped with a pneumatic cylinder for controlled opening and closing of bed. Bed shall be secured to metal mounting chassis with a concealed steel-on-steel hinge. No hinge structure shall be exposed on interior or exterior surfaces. Unit shall have mounting hardware included. Unit shall have Microban® antimicrobial embedded into plastic material on the changing surface. Unit shall conform to ANSI S117.1 Accessible and Usable Building and Facilities, ASTM F 2285-04 Standard Safety Performance Specification for Diaper Changing Tables for Commercial Use, ANSI Z535.4 Product Safety Signs and Labels, EN 12221:2008, ASTM G22 Antibacterial standards or local code if more stringent installation requirements are applicable for Barrier-Free accessibility. Unit shall comply with ADA regulations when properly installed. Bed shall have smooth concave changing area with a nylon safety strap and two hooks for bags or purses.
      Unit shall have a built-in Liner Dispenser for use with 3-ply chemical free biodegradable bed liners, instructional graphics and safety messages in 4 languages. Optional Braille label is available. Unit shall be backed by manufacturer’s 5-year limited warranty on materials and workmanship and include a provision for replacement caused by vandalism. Unit shall be manufactured in the U.S.A.

      INSTALLATION:
      To ensure proper installation and compliance to building codes, it is recommended that a qualified person or carpenter perform the installation of the unit. The unit must be properly installed onto a permanent wall that is capable of supporting significant weight and can accommodate the supplied installation hardware. The Koala Baby Changing Station meets ADA regulations when properly installed.
      Drilling holes and mounting the station:
      1. Remove changing station from the shipping container and check for any freight damage. If damage is found, please call Koala Kare Products’ Customer Service at 888.733.3456. Remove “Installation Kit” and “Operator Kit” from box. Please give “Operator Kit” to facility manager or operator. Box should contain two pieces: the bed and metal mounting chassis and the wall mount liner dispenser. Identify the best location for installing the unit.
      2. Standard Installation- Remove the bed and chassis from the box and select the wall area where the unit will be installed. Make sure you have taken into consideration the operating clearance of 9½” (241.3 mm) on both sides of the exposed chassis and 22” (558.8 mm) from wall surface when open. Measure from the floor 44¼” (1123.95 mm) on stud center and mark the wall. The mounting holes are designed for 16” stud centers. Ensure the locations you have marked for the mounting holes are level before drilling. Drill pilot holes for keyhole mounting using a 1/8” regular drill bit.
      Masonry or Tile over Stud Wall- Use a 7/32” (5.56 mm) masonry drill bit for the pilot hole until you hit the stud. Change bit to 1/8” (3.18 mm) regular drill bit.
      Metal Stud or Concrete Block- If the wall has wood studs that are not on 16” (406.4 mm) centers, has metal studs or an underlying surface of concrete block, drill with a ½” (12.7 mm) masonry bit. (You may have to purchase toggles before installing.) You must allow a minimum of inside wall space for toggles to turn depending on toggles used. Insert and tighten toggles.
      3. Screw two of the mounting screws into the pilot holes leaving ¼” (6.35 mm) exposed to allow keyhole slots to be easily mounted over the screw heads. Place chassis over screws. After securing the unit using the keyhole slots, verify that the unit is level. Tighten top two screws so that they are flush with the wall. Use the four lower holes as a guide to mark and drill pilot holes. Use remaining four screws and four washers to complete installation of bed and metal mounting bracket. Insert washers over lower four screws. All SIX screws and four washers must be mounted to the chassis.
      4. Ensure liner dispenser is free from damage. Remove key, unlock, and open liner dispenser lid. This will expose liner dispenser mounting holes. Line up dispenser mounting holes onto chassis and secure with the four screws provided. Close and lock the liner dispenser door.
      5.Clean work area and inspect unit to ensure it opens and closes smoothly. Give Operator Kit and key to the facility operator. Replacement parts and additional liners can be purchased from your local distributor or by calling Koala at 888.733.3456 or 303.539.8300.
      The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions without notice.

      review board - 상품후기 전체보기

      review 작성 폼
      review board
      이 름 :
      평점 :      
      내용
      후기쓰기
      review 리스트
      이름
      내용
      평점
      날짜

      QnA board - 상품문의 전체보기 상품문의

      QnA 리스트
      등록된 문의가 없습니다.

      review board - 상품후기 전체보기 후기쓰기

      review 리스트
      등록된 리뷰가 없습니다.

      Item size chart 사이즈 기준표

      * 상품사이즈 치수는 재는 방법과 위치에 따라 1~3cm 오차가 있을 수 있습니다.

      비밀번호 확인 닫기